Skip to main content

Change location

You are currently on the Slovakia (Slovak) website

My country is not on the list

Global

  • Bracco.com (English)

Asia

  • China (中文)
  • Japan (日本語)
  • South Korea (한국어)

Americas

  • Brazil (Português)
  • Canada (English)
  • Mexico (English)
  • Canada (Français)
  • USA (English)

Europe

  • Austria (English)
  • Belgium (English)
  • Czech Republic (English)
  • Denmark (English)
  • Finland (English)
  • France (Français)
  • Germany (Deutsch)
  • Iceland (English)
  • Italy (Italiano)
  • Luxembourg (English)
  • Norway (English)
  • Poland (English)
  • Slovakia (English)
  • Sweden (English)
  • Switzerland (English)
  • The Netherlands (English)
  • UK (English)
  • Careers
  • Media and News
  • Get in touch
    • Slovakia (English)
  • Home
  • we are bracco
    We are Bracco

    Welcome to a World of contrasts

    • Our businesses
    • Purpose and values
    • Our history
    • Our Foundation
    • Responsibility and Ethical conduct
  • Our Portfolio

    Proven offerings for a proven difference

    • X-ray/CT
      • Contrast agents

        • Iomeron
        • Iomeron 400
      • Medical devices

        • CT Exprès
        • Empower CTA+
    • MRI
      • Contrast agents

        • ProHance
      • Medical Devices

        • Empower MR
    • Ultrasound
      • Contrast agents

        • Sonovue
    • Nuclear medicine
    • Interventional cardiology
      • Medical devices

        • ACIST CVi
    • Digital solutions
    • Oncology
    • Cardiology
  • Woman looking into microscope
    Innovation

    A deep dive into our R&D progress

    • Digital future
    • R&D
    • The Bracco sites
    • Scientific heritage and patents
  • knowledge
    Knowledge

    Current activities and future opportunities

    • E-learning
    • Partnerships in education
    • Events
  • Ceriano Laghetto
    Sustainability

    Our game plan and goals for a better world

    • Our sustainability pillars
    • Governance and transparency
    • Sustainability report
  • Our Stories
  1. Home
  2. Our Portfolio
  3. X-ray/CT
  4. Contrast agents

  5. Iomeron 400

Iomeron 400

 

Ak ide o najvyššiu koncentráciu jódu 1,2,3,4,5

 

Iomeron® je trojjódové neionogénne monomerné kontrastné médium pre rádiológiu 7

Iomeron® má zaujímavé priaznivé vlastnosti, napríklad:

 

  • najnižšiu viskozitu pri danej koncentrácii medzi iso-osmolálnymi kontrastnými médiami (IOCM) a nízkoosmolálnymi kontrastnými médiami (LOCM) 7;
     
  • najnižšiu osmolalitu medzi monomernými LOCM 7;
     
  • zloženie s najvyššou koncentráciou jódu (400 mg/ml) dostupnou na trhu. 

 

Injekčné riešenie s vyššou koncentráciou jódu umožňuje vyššie špičkové zvýšenie kontrastu po kratšom čase od podania v porovnaní s podaním látky s nižšou koncentráciou jódu v rovnakom objeme a pri rovnakej rýchlosti prúdenia 8.

Iomeron® (Iomeprol) je kontrastná látka poslednej generácie od firmy Bracco. Táto trojjódová neionogénna kontrastná látka bola uvedená na trh v roku 1995 9 ,a rýchlo sa stala najobľúbenejším kontrastným médiom mnohých klinických lekárov 9. Jeho unikátny a inovatívny profil sa môže pochváliť najvyššou koncentráciou (400 mg/ml) zo všetkých neionogénnych médií, ktorá kedy bola na svete povolená  10.

 

Iomeprol je teraz registrovaný vo viac ako 40 krajinách po celom svete vrátane všetkých významných štátov v Európe a na Strednom východe, v Japonsku a v ázijsko-pacifickej oblasti. Toto médium predstavuje vo svojej triede krok vpred. Iomeprol sa najobľúbenejším médiom mnohých lekárov stal z mnohých dôvodov, okrem iného:

 

  • ide o unikátny produkt spájajúci najnižšiu viskozitu medzi neionogénnymi médiami a veľmi nízku osmolalitu v porovnaní s inými dostupnými monomernými neionogénnymi médiami 10;
     
  • Iomeron® je pre klinické použitie ľahko dostupný v mnohých rôznych koncentráciách jódu a mnohých objemoch;
     
  • pri zobrazovaní pomocou prvého priechodu CT dokáže Iomeprol 400 mg/ml pri rovnakej celkovej dávke jódu a rýchlosti prúdenia priniesť zvýšenie kontrastu a lepšiu kvalitu obrazu než kontrastné látky s nižšou koncentráciou jódu 11, 12, 13;
     
  • randomizovaná, paralelná a dvojnásobne slepá porovnávacia štúdia, ktorá skúmala použitie Iomeronu a Iodxanolu  v koronárnom CTA na niekoľkých rôznych pracoviskách zaznamenala, že stredné zmeny tepu srdca po intravenóznom podaní kontrastnej látky boli v skúmanom čase spravidla malé a boli porovnateľné u látok Iomeron-400 a Iodixanol 320 14;
     
  • prospektívna intraindividuálna štúdia ukázala, že postup využívajúci pri CTA vyšetreniach vystavenie nízkym dávkam radiácie v spojení s použitím látky Iomeron-400 spôsobuje podstatne nižšiu radiačnú expozíciu pri zachovaní konštantnej CNR a dobrej kvality obrazu v porovnaní s bežným postupom využívajúcim kontrastné médium s nižšou koncentráciou 15;
     
  • rozsiahla štúdia porovnávala účinky látok Iomeprol-400 a Iodixanol-320 na fungovanie obličiek u pacientov s chronickým ochorením obličiek (CKD) pri vyšetreniach počítačovou tomografiou. Na základe výsledkov prišli autori štúdie k záveru, že: „Výskyt CIN bol u pacientov so stredne až veľmi vážnym CKD významne vyšší po IV. podaní Iodixanolu-320 než Iomeprolu-400. Aj stredný nárast SCr od základnej hodnoty bol vyšší u pacientov dostávajúcich Iodixanol. Pre nefrotoxicitu jednotlivých kontrastných médií môžu byť významné aj iné vlastnosti než osmolalita.“ 16.

 

Nefropatia spôsobená kontrastnou látkou (CIN)

1) High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography:iopromide 370 versus iomeprol 400.

 

Cademartiri F, de Monye C, Pugliese F, Mollet NR, Runza G, van der Lugt A, Midiri M, de Feyter PJ, Lagalla R, Krestin GP.Invest Radiol. 2006 Mar;41(3):349-53.

 

View

 

 

 

2) MDCT angiography of the pulmonary arteries: influence of iodine flow concentration on vessel attenuation and visualization.

 

Schoellnast H, Deutschmann HA, Fritz GA, Stessel U, Schaffler GJ, Tillich M. AJR Am J Roentgenol. 2005 Jun;184(6):1935-9.

 

View

 

 

 

3) Does iodine concentration affect the diagnostic efficacy of biphasic spiral CT in patients with hepatocellular carcinoma?

 

Marchianò A., Spreafico C., Lanocita R., Frigerio L., Di Tolla G., Patelli G., Garbagnati F., Heiman F., Taroni P., Damascelli B. Abdom Imaging. 2005 May-Jun;30(3):274-80.

 

View

 

 

 

4) Multidetector-Row Computed Tomography

Hammerstingl et al.

 

 

 

5) Effect of iodine concentration of contrast media on contrast enhancement in multislice CT of the pancreas.

 

Fenchel S, Fleiter TR, Aschoff AJ, van Gessel R, Brambs HJ, Merkle EM.Br J Radiol. 2004 Oct;77(922):821-30.

 

View

 

 

 

6) Enhancement and safety of iomeprol-400 and iodixanol-320 in patients undergoing abdominal multidetector CT.

 

Romano L, Grazioli L, Bonomo L, Xu JR, Chen KM, Dore R, Vanzulli A, Catalano C. Br J Radiol. 2009 Mar;82(975):204-11. Epub 2008 Dec 8.

 

View

 

 

 

7) The chemistry of iomeprol and physico-chemical properties of its aqueous solutions and pharmaceutical formulations.

 

Gallotti A, Uggeri F, Favilla A, Cabrini M, de Haën C.Eur J Radiol. 1994 May;18 Suppl 1:S1-12.

 

View

 

 

 

8) Computed Tomography Contrast Enhancement Principles and the Use of High-Concentration Contrast Media.

 

Herman S.J., Comput Assist Tomogr. 2004 Jul-Aug;28 Suppl 1:S7-11.

 

View

 

 

 

9) Bracco internal data.

 

 

 

10) Iomeron® SPC

 

 

 

11) 16MDCT angiography of aortoiliac and lower extremity arteries: comparison with digital subtraction angiography.

 

Albrecht T, Foert E, Holtkamp R, Kirchin MA, Ribbe C, Wacker FK, Kruschewski M, Meyer BC. AJR Am J Roentgenol. 2007 Sep;189(3):702-11.

 

View

 

 

 

12) High-concentration contrast media (HCCM) in CT angiography of the carotid system: impact on therapeutic decision making.

 

Schuknecht B. Neuroradiology. 2007 Jul;49 Suppl 1:S15-26.

 

View

 

 

 

13) Does iodine concentration affect the diagnostic efficacy of biphasic spiral CT in patients with hepatocellular carcinoma?

 

Marchianò A, Spreafico C, Lanocita R, Frigerio L, Di Tolla G, Patelli G, Garbagnati F, Heiman F, Taroni P, Damascelli B.Abdom Imaging. 2005 May-Jun;30(3):274-80.

 

View

 

 

 

14) Multicenter comparison of high concentration contrast agent iomeprol-400 with iso-osmolar iodixanol-320: contrast enhancement and heart rate variation in coronary dual-source computed tomographic angiography.

 

Becker CR, Vanzulli A, Fink C, de Faveri D, Fedeli S, Dore R, Biondetti P, Kuettner A, Krix M, Ascenti G. Invest Radiol. 2011 Jul;46(7):457-64.

 

View

 

 

 

15) Low-dose multidetector-row CT-angiography of abdominal aortic aneurysm after endovascular repair.

 

Iezzi R, Cotroneo AR, Giammarino A, Spigonardo F, Storto ML. Eur J Radiol. 2011 Jul;79(1):21-8. Epub 2009 Dec 16.

 

View

 

 

 

16) The ACTIVE Trial: comparison of the effects on renal function of iomeprol-400 and iodixanol-320 in patients with chronic kidney disease undergoing abdominal computed tomography.

 

Thomsen HS, Morcos SK, Erley CM, Grazioli L, Bonomo L, Ni Z, Romano L; Investigators in the Abdominal Computed Tomography: IOMERON 400 Versus VISIPAQUE 320 Enhancement (ACTIVE) Study.Invest Radiol. 2008 Mar;43(3):170-8.

 

View

1) Intravenous contrast material administration at helical 16-detector row CT coronary angiography: effect of iodine concentration on vascular attenuation.

 

Cademartiri F, Mollet NR, van der Lugt A, McFadden EP, Stijnen T, de Feyter PJ, Krestin GP.Radiology. 2005 Aug;236(2):661-5.

 

View

 

 

 

2) Improving diagnostic accuracy of MDCT coronary angiography in patients with mild heart rhythm irregularities using ECG editing.

 

Cademartiri F, Mollet NR, Runza G, Baks T, Midiri M, McFadden EP, Flohr TG, Ohnesorge B, de Feyter PJ, Krestin GP.AJR Am J Roentgenol. 2006 Mar;186(3):634-8.

 

View

 

 

 

3) Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography.

 

Cademartiri F, Maffei E, Palumbo AA, Malagò R, La Grutta L, Meiijboom WB, Aldrovandi A, Fusaro M, Vignali L, Menozzi A, Brambilla V, Coruzzi P, Midiri M, Kirchin MA, Mollet NR, Krestin GP.Eur Radiol. 2008 Mar;18(3):576-83. Epub 2007 Oct 13.

 

View

 

 

 

4) Effect of iodine concentration of contrast media on contrast enhancement in multislice CT of the pancreas.

 

Fenchel S, Fleiter TR, Aschoff AJ, van Gessel R, Brambs HJ, Merkle EM.Br J Radiol. 2004 Oct;77(922):821-30.

 

View

 

 

 

5) Detection and localization of acute upper and lower gastrointestinal (GI) bleeding with arterial phase multi-detector row helical CT.

 

Jaeckle T, Stuber G, Hoffmann MH, Jeltsch M, Schmitz BL, Aschoff AJ.Eur Radiol. 2008 Jul;18(7):1406-13. Epub 2008 Mar 20.

 

View

 

 

 

6) Image quality in CT perfusion imaging of the brain. The role of iodine concentration.

 

König M, Bültmann E, Bode-Schnurbus L, Koenen D, Mielke E, Heuser L.Eur Radiol. 2007 Jan;17(1):39-47. Epub 2006 May 16.

 

View

 

 

 

7) MDCT angiography for detection of pulmonary emboli: comparison between equi-iodine doses of iomeprol 400 mgI/mL and iodixanol 320 mgI/mL.

 

Langenberger H, Friedrich K, Plank C, Matzek W, Wolf F, Storto ML, Schaefer-Prokop C, Herold C.Eur J Radiol. 2009 Jun;70(3):579-88. Epub 2008 Apr 1.

 

View

 

 

 

8) Clinical value of MDCT in the diagnosis of coronary artery disease in patients with a low pretest likelihood of significant disease.

 

Nikolaou K, Rist C, Wintersperger BJ, Jakobs TF, van Gessel R, Kirchin MA, Knez A, von Ziegler F, Reiser MF, Becker CR.AJR Am J Roentgenol. 2006 Jun;186(6):1659-68.

 

View

 

 

 

9) Effects of non-ionic iodinated contrast media on patient heart rate and pressures during intra-cardiac or intra-arterial injection.

 

Schmid I, Didier D, Pfammatter T, Garachemani A, Fleisch M, Kirchin MA, Meier B.Int J Cardiol. 2007 Jun 12;118(3):389-96. Epub 2007 Mar 21.

 

View

 

 

 

10) Optimization of cardiac MSCT contrast injection protocols: dependency of the main bolus contrast density on test bolus parameters and patients' body weight.

 

Rist C, Becker CR, Kirchin MA, Johnson TR, Busch S, Bae KT, Leber AW, Reiser MF, Nikolaou K.Acad Radiol. 2008 Jan;15(1):49-57.

 

View

Iomeron 150-200-250-300-350-400 Súhrn charakteristických vlastností lieku(PDF) 10/14/2022 pdf Download
MDCT E-lectures
View

SLUŽBY TÝKAJÚCE SA PRODUKTOV

 

Ak máte nejaké otázky ohľadne niektorého produktu Bracco Imaging.

 

[email protected]

SLUŽBY PRE PROFESIONÁLOV

 

Skupina profesionálnych služieb je k dispozícii zdravotníckym profesionálom, ktorí potrebujú vedecké či lekárske informácie o produktoch spoločnosti Bracco Imaging.

 

[email protected]

SLUŽBY ZÁKAZNÍKOM

 

Tu získate informácie, ako podať objednávku. Tu tiež môžete kontaktovať nákupné oddelenie.  

 

[email protected]

Kontaktuj nás


Vyplňte prosím formulár nižšie a my sa vám ozveme späť.

Different countries may have specific processes in place to handle reports of adverse reactions. To report an adverse reaction related to Bracco products, you can find specific contacts and information selecting the page "Pharmacovigilance" of your country.

I have read and I agree with the Bracco Privacy Policy

* I have read the BraccoHealthCare Professionals Privacy Notice and I consent to the processing of my personal data allowing Bracco Imaging SpA (Data Controller) to conduct its business or scientific operations and contact me with promotional communication through email, SMS, and other digital and offline channels, such as mobile apps and social media.

DISCLAIMER

 

For any product or type of product, whether a drug or device, referenced in this website, physicians should carefully review the product's package insert, instructions for use, or user manual prior to patient administration to ensure proper utilization of the product. The local Summaries of Product Characteristics of the main Bracco Imaging products are available on line.

Please login to DocCheck
to view our products

Register here Forgot your password?

The Bracco Group is an international group of highly specialized companies.
We are an active part of the healthcare sector, and a global leader in diagnostic imaging.

  • We are Bracco
  • Our Portfolio
  • Innovation
  • Knowledge
  • Sustainability
  • Our Stories
  • Farmakovigilancia
  • Data Protection

Connect with us

Via Egidio Folli 50
20134 Milan, Italy
Phone + 39 02 2177.1

  • Terms of Use
  • Privacy Policy
  • Cookie Policy
  • Imprint
  • for Bracco VPN users

Bracco Copyright © 2025 | Registered office: Via E. Folli, 50, 20134 Milano, Italy | Share Capital € 104.000.000 f.p. | VAT Milan Comp. Reg. n. 00825120157 | Milan REA n. 348182